|
|
|||||||||
![]() ![]() |
|||||||||
|
|
|||||||||
The following contribution is meant to specify the “natural enemies“ of signal integrity and to sensitise to the fact that with parsimony, you easily back the wrong horse in this particular field. Or, put into positive words: It’s worth the effort to look for the right partner. After all, the complete information chain that even includes peripherals is decisive for the quality and immunity to interferences and fault tolerance. Our considerations are based on serial data transmission. The standardisation committees at PICMG and VITA realised at an early stage that for high-speed applications, you have to dismiss classical bus structures and switch over to point-to-point connections with differential pairs. To avoid the formation of long sequences of logical zeros and ones on serially transmitted data packets – which complicate clocking and data regeneration – the 8B/10B encoding is successful in such applications.
8B/10B encoding When using 8-bit words, you will get 256 (2 8 ) possible bit combinations, 10-bit sequences however, result in 1024 possible bit combinations. For the formation of 8-bit words, the 8B/10B code only uses such bit combinations that provide multiple state changes. These are words which contain a maximum sequence of 5 zeros or 5 ones in a row. Thus it is possible to safely generate a clock signal that is required for synchronisation from a coded signal with an adequate number of state changes. Thanks to these advantages, the 8B/10B encoding is used in the Gigabit Ethernet, the 10-Gigabit-Ethernet, with Fibre-Channel, StarFabric and generally with ATM (Asynchronous Transfer Mode) interfaces. MicroTCA, the latest development of the AdvancedTCA standards which promises particular success, offers the possibility to transmit data by Gigabit Ethernet, PCI-Express, Serial Rapid I/O, Serial Attached SCSI or Advanced Switching. At first, the question arises why to make highly crucial reflections on signal integrity. After all, it’s a XAUI transmission by means of an NRZ signal with a data rate of „only“ 3.125 Gbps (XAUI = X Attachment Unit Interface, an interface used in the 10-Gigabit-Ethernet; NRZ = “Non-Return-to-Zero” signal, a signal that does not return to zero at regular intervals). It is a fact, however, that the edge steepness of the signals determines the bandwitdth. Thus, at a basic frequency of 3.125 GHz, the signal integrity for a bandwidth of at least 15.625 GHz has to be guaranteed. This is due to the high-frequency, low-level harmonic waves, strictly speaking to the 5th harmonic wave according to Fourier. With MicroTCA, Advanced Mezzanine Cards (AMC) are defined as smallest modular assembly. For cost reduction reasons, this technology uses contacting via connectors on the backplane and gold pads directly on the AMC board. Due to their small mechanical shape, 170 contacts have to be realized via these connectors on a width of only 73.5 mm. To investigate the performance of different printed conductor geometries, Elma Trenew Electronic GmbH, as an experienced specialist in the field of backplane and basic systems, carried out fundamental metrological examinations. For this purpose, a MicroTCA test backplane with appropriate high-quality test boards was developped. It served to measure the physical properties by means of a TDR (Time Domain Reflector) and VNA (Vector Network Analyzer). These measurements assisted in deriving decisive findings on important influencing quantities that affect signal integrity. The ISI effect: Maximum influence on signal integrity The measurements showed that the Inter Symbol Interference (ISI) effect decisively influences signal integrity. The ISI effect describes how pulse-shaped signals are broadened compared to the output signal through dispersion, skin effect, dielectric losses and reflections. In addition, the inductive stub effects (with THT connectors) or bone effects of up to 1.2 nH (that occur when connecting SMT connectors to the inner layers of the backplane) contribute to the ISI effect. Since the pulses can be broadened through Inter Symbol Interference over several periods, this effect limits the transmission bandwith that can be used actually. But it’s not only one interference factor. Beside the factors described above, another important item has to be mentioned: cross-talking between differential pairs. Ideally, neighbored pairs are separated from each other and shielded by ground planes in which case only few “aggressors“ could influence the individual pair. In practical operation, the high number of layers of the board necessary for doing so, and thus the high costs involved and the manufacturing difficulties speak against it. Plus, the stub effect becomes more and more important with an increasing board thickness. The experiments also showed that in the backplane, the signal is considerably invalidated due to attenuation and losses. X-talk (crosstalk) on the other hand dominates in the connector. For this reason, the relevant parameter for x-talk measurements is the NEXT (Near Ended Crosstalk) parameter. Oddly enough, FEXT (Far Ended Crosstalk) benefits from the attenuation on the board and can be neglected provided that this influence now is known. What does this mean in practice? For this purpose, and for the exact detection of the thermic situation in the test structure, up to 20 temperature sensors can be positioned in the shelf. The system can be enlarged with maximally 12 AMC, 8 “full height” and 4 “half height” in accordance with the form factor. All modules are Hot Swap components and IPMI-controlled. The inserted backplane benefits already from the results of the detailed series of measurements described above. It has a 20 layer structure and guarantees optimum signal integrity. Plus, it supports all FRU (Field Replaceable Unit) functions. High speed routing is effected via DualStar technology, the FCI connectors used are developed especially for high-speed data transfer. Two options are available for telecommunication and non-telecommunication applications.
<< back |
|||||||||
![]() |